• Products
  • L124 IVF Workstation
  • L124 IVF Workstation

    Our Workstations are designed for optimal working conditions in the Embryo and Andrology lab and to provide a safe and optimized environment for oocytes, spermatocytes and embryos.

    The 100 series provides protection and heating for the sample and offers the broadest variety of features and models.

    Standard Features

    Stainless Steel Table Top
    Integrated Alu Heat System
    Mounting Assembly for most Stereo Microscopes
    Microscope Light Opening with Heated Glass Ø90
    Integrated Gassing and Humidification System
    Eye Draught Protection
    2 Electrical Outlets inside the cabinet
    Support Stand


    RIWitness-ready-sticker

    K-Systems L124 Workstation

    Key Features of IVF Workstations 100 Series

    The air flow is filtered through a VOC prefilter and HEPA filter to ensure filtered Grade A air quality

    HEPA filter classification H-14 according to DIN EN 1822 removes at least 99.995 % of all airborne particles down to 0.3 microns.

    ALU Heat System with 3 individual temperature sensors to ensure high temperature stability  at +/- 0.4 oC over the work area (6 sensors in L126Dual)

    Incorporated K-SYSTEMS Heated Glass Stage at temperature stability +/-0.7 oC

    Airflow 0.32 m/s

    Integrated Humidified Gas System

    Operator and ergonomically friendly

    Various optional features

    RI Witness ready

    Standard Features for IVF Workstations 100 Series

    Heated Area

    K-SYSTEMS well proven Alu HeatTM System provides the most precise temperature control.

    • The heat distribution is controlled in
    • Calibration of each heating zone can be seen and adjusted at the main control panel.
    • Each heating zone is individual calibrated with specialized software to monitor each zone and ensure a uniform heat distribution.
    • The unique design of the Alu Heat systems ensures excellent heat transfer to the samples and avoidance of temperature overshoot.
    • The unit temperature is constantly being displayed on the front panel of the work area.

    Alu Heat System with 4+1 zones and Edge Enhancement system is standard in L234

    Alu Heat System with 3+1 zones is standard in L100 and L200 series.

    RI Witness

    RI Witness uses Radio Frequency Identification (RFID) technology to monitor all critical work carried out in the Laboratory, creating a complete record of each stage of a patients cycle.

    RI Witness is watching, tracking and recording all of the time and Locks the patients identity to the sperm, eggs and embryos at every stage of the treatment.

    The system also actively prevents patients samples coming into proximity with those of other patients and gives everyone peace of mind that the best possible processes are being employed.

    Heated Glass Stage

    K-SYSTEMS has developed and produced a controlled heating temperature system which is integrated in the microscope light opening.

    • Light opening Ø90 mm standard L100 and L200 series
    • Excellent heat distribution and stability
    • Robust and cost efficient

    glass_stage_diode_small

    Heated Glass Stage Ø90 mm with integrated LED.

    Temperature accuracy of +/- 0.4oC

    Outstanding heating technology

    As embryos are sensitive to temperature fluctuations a controlled heating temperature system is integrated in the microscope light opening. The system is controlled on the control panel and provides the highest stability possible of the media in the culture dishes during microscopy.

    All L100 have heated glass Ø90 mm as standard feature.

    The Gassing and Humidification System  – Maintain the pH in the media during operations.

    Integrated Gassing and Humidification System

    gassing_100As a standard, the 100 series has an integrated gas humidification system. Pre-mixed gas is required.
    nozzles_tableThe pre-mixed gas is humidified through a heated gas washing system and extruded through nozzles in the table plate covered by glass

    hoods (glass hoods optional). With the regulator you can adjust the level of humidification by adjusting the gas flow. The gas flow can be adjusted between 0-50 ltr/h.

    The humidified and heated gas is diffused through 2 nozzles in the table plate. To maintain the pH in the media glass incubator hoods can be used.

    GHE2

    An optional solution in the 100 series is to have the humidified gas diffused through connectors in the inner wall using silicone tubes connected to glass hoods (glass hoods optional).

    ghe2

    The Front Window

    Eye-draught-protection

    Eye Draught Protection

    Eye Draught Protection is an easily adjustable plate that slides to the top of the microscope and thus prevent draught flow to trouble the operator eyes.

    Standard in L124IVF, L126IVF, L126Dual and L126MP.

    slidingwindow

    Sliding Window

    Sliding Window is provided with a slider to adjust the device vertically. This makes it easy to adapted to any microscope and desired working height.

    Standard in L200 Series

    Fixed Window

    A semi-circle cutout in the front window ensures space to adjust the height of the microscope in order to achieve the desired working height.

    Standard in L124 ICSI and L125

    Optional Features for IVF Workstations 100 Series

    Monitor

    Fully Sealed 19″ high resolution monitor.
    An excellent tool for viewing, training and education.
    The viewing panel of glas is designed to non disturbance of the air flow and easy to clean.
    The monitor supports most of the signals coming from modern digital cameras and supports DVI, HDMI as well as analog signals.
    Connect the monitor to your external PC and you bring the pictures right into your office or meeting room.

    K-Systems Monitor

    Micro Incubator

    Build-in 15 ltr Micro Incubator.
    To optimize your Work conditions inside the Work area, and to reduce the frequency of opening of large CO₂ incubators, a 15 ltr Micro Incubator can be an Integrated part of your Workstation.

    The Micro Incubator has two shelves and a two level alarm system. As an option a glass inner door can be supplied.

    micro_incubator

    Heated Pass Through Tunnel

    To improve the Work flow and to reduce the time of handling oocytes in an unheated and unstable environment, the Heated Pass Through Tunnel is a great alternative to a hatch in the door between the aspiration room and the embryo lab.

    The Heated Pass Through Tunnel is made of stainless steel with Integrated heating elements and top hinged polycarbonate lid.

    micro_incubator

    Stands for IVF Workstations

    Ergonomic elevation support stand for your IVF Workstation.

    The K-SYSTEMS® Support Stand with Electrical Adjustable Height will offer you maximum comfort, either sitting or standing

    Features:

    • Adjust the work height exactly to your need with this smooth non-step elevation system
    • A simple touch of the button will adjust precisely the work height in the range of: 790-1110 mm
    • Stability and safety developed in accordance with EN 61010 assures high stability also at highest elevation level
    • The use of high quality components ensures the highest level of usability
      Compatible with existing 100 and 200 series Workstations (except MP and ICSI versions)

    Stand with shelf for computer for your IVF Workstation

    Integration of the computer in the support stand of your Workstation will offer you several advantages.

    • More easy cleaning under and around the Workstation
    • Cables and fittings becomes integrated part of the support stand
    • No more loose hanging cables
    • All details prepared to ensure a high level of usability

    Integrated Keyboard Shelf


    Can be integrated into workstations in the L100 and L400 series (except L124 ICSI).

    Can be reinstalled on all Workstations in the L100 and L400-series, manufactured after 2010 (exceptL124 ICSI).

    Integrates with both Standard Stand, Electrical Adjustable Stand and Stand with Shelf.

    Many different positions depending on the client’s needs

    Max load 10 kg

    Combined with Stand with Shelf it represents the perfect solution for PC.

    Dimensions

    Shelf surface area: 418 x 313 mm (Length x Breadth).
    Height of shelf including mounting brackets: 107 mm.
    Distance from top of shelf to lower surface of the table: Approx 70 mm.

     

    Light Source with LED Light

    Light sources for stereo microscopes. Conveniently mounted underneath the table top leaving a smooth and even surface above.

    LS112  for 100 series.

    The LED light is clear and safe and enables the user to get fast and accurate results in observation of embryos.

    • The clear LED light gives you the highest intensity in the visual field.
    • Durable – up to 35.000 hours of continuous light.
    • No light in the UV spectrum
    • Easily adjustable dark and light field illumination
    • Slot for filter installation (red, blue, green filter)
    • Low power consumption

    LS112 LED for 100 series.

    High end illumination system features two condenser lenses, 360 degree rotational and 40 mm horizontally moveable two sided mirror.

    Slot for filter installation (red, blue, green filter).

    Overall Dimensions (WxDxH)
    1246x735x2020 mm
    Workspace/tabletop
    1226×553 mm
    Standard Working Height
    835mm – 860mm
    Distance from tabletop to HEPA-filter
    710 mm
    Power Consumption
    552 watt
    Mains Voltage
    230VAC or 115 VAC
    Mains Frequency
    50Hz/60Hz or 60Hz
    Required Power
    2.4 A / 4.8 A
    Order Number  Description
    4,111,211,121 WS L124 IVF 115V Right
    4,112,211,121 WS L124 IVF 115V Right Monitor
    4,111,311,121 WS L124 IVF 115V Right RI Witness
     4,112,311,121 WS L124 IVF 115V Right RI Witness Monitor
     4,111,212,121  WS L124 IVF 230V Right
     4,112,212,121  WS L124 IVF 230V Right Monitor
     4,111,312,121  WS L124 IVF 230V Right RI Witness
     4,112,312,121  WS L124 IVF 230V Right RI Witness Monitor

    Order codes for additional features and options of the L124 IVF Workstation

    Order Number  Description
    12141 Stand L124 & L234
    12142 Stand w/shelf L124
    12110 El. Adj. stand L124 230V
    12110-a El. Adj. stand L124 120V
    12180 Keyboard shelf
    41093 LED Lightsource LS112
    41103-1 Green Filter for lightsource, LS112, LS12
    41104-1 Red Filter for lightsource, LS112, LS12
    41105-1 Blue Filter for lightsource, LS112, LS12
    52268 Keyboard