• Products
  • G210 InviCell
  • G210 InviCell

    Long Term Incubator

    Encapsulating 20 years of incubator development, the G210 InviCell incubator combines optimal embryo growth conditions with advanced user control. It is the ideal incubation solution for a busy clinic.

    • Defining, Creating, Monitoring and constantly sustaining the optimal environment for human embryos
    • Thoughtful design and advanced user control options make everyday work with the G210 effective, safe and comfortable
    • With its compact size, low daily running costs and the option of a stacking system the G210 is the ideal solution for a busy Clinic

    Combining optimal embryo growth conditions with advanced user control

    G210-with-features

    Key Features of G210 InviCell and G210 InviCell Plus

    Space Saving

    Ten individual incubation chambers to ensure minimal stress and risk of cross contamination for the embryos. Significant space saving

    Heating

    Dedicated heating plates with grooves ensure direct heat transfer to the dish

    Responsive Gas Control

    Set the required specifications to mix CO2 and O2. Uses pure CO2 and N2 (optional)

    Optimal Environment

    Embryo conditions, including pH levels, are kept completely stable through advanced and accurate software control of gas and temperature thus providing stress free incubation

    Ambient humidity

    The G210 is an incubator with ambient humidity which strongly minimizes the risk of fungal growth inside the incubator and makes it easier to clean

    Safe

    Electro-magnetic fields eliminated by non-inductive EM Neutra™ technology (patented)

    Superior Filtering and Hygiene

    High efficiency particle filter to remove airborne particles. VOC filter to remove organic compounds

    Tracking and Alarm

    Data logging and alerts with K-Link™ extensive ethernet based monitoring

    Advanced User Control

    Advanced intuitive user interface with dedicated security system

    Economical

    Low running costs because of low gas consumption and use of pure gas

    Independent External monitoring

    An option for independent external monitoring of key parameters including temperature and gas concentration

    Certified

    CE Marked

    Optimal Environment for Human Embryos

    g210

    Decreasing embryo stress is a key factor in long term incubation.

    The G210 has several characteristics to ensure minimal stress.
    Highly stable environment of both gas and temperature
    VOC filter, HEPA14 filter and UV light* (*Not available in the USA) ensuring clean air in the chambers
    Individual chambers for each patient- 10 in total

    Optimal temperature conditions at all times. The advanced heating system of the G210 ensures constant and all-embracing heating in the chambers

    • Each isolated chamber has its own temperature sensor to ensure quick and accurate temperature control of all 6 sides in the chamber
    • The unique non-inductive EM NeutraTM heating system gives no electro-magnetic fields around the embryos
    • Emulate the natural cycle of basal body temperature with the advanced software based heating technology

    Embryo conditions including pH levels are kept stabile through the combination of accurate gas and temperature control.

    • Increased accuracy and stability with dedicated gas control algorithms
    • The built-in advanced gas mixer allows gas concentration to be set at the required level
    • Ambient humidity based incubation significantly reduces the risk for fungal growth and cross contamination
    • The unidirectional gas flow system ensures even gas distribution throughout the chambers
    • To optimize recovery time and keep gas consumption low, gas flow is paused when the lid is open

    Advanced User Control

    Large 7“ touch-screen display gives you intuitive control of all
    parameters and on screen data display.

    A quick overview of each chamber and key parameters on screen

    Enter patient data directly on the screen for each individual. No more writing on the device with markers or pens

    Multi-level password protection ensures no unintended access to settings

    Graphic display of key parameters over time

    React quickly to changes in the incubator with the extensive audible and visible monitoring and alarms. Alarms can easily be transferred to the hospital central monitoring system.

    Temperature – Gas – Service needs

    Keep Track of Incubator from anywhere in the Clinic

    K-Link Ethernet based monitoring system
    Monitor all your incubators directly from your office. The K-Link Ethernet based software provides external monitoring of all key parameters in your G210 InviCell. Multiple G210s can be monitored from the same PC.

    Parameters continuously monitored with K-Link:
    – Temperature per chamber
    – CO2 and O2 levels
    – Gas pressure and consumption
    – Alarms and warnings
    – Service requirements

    K-Link E-mail alerts
    In case of an alarm K-Link can be set up to automatically send an e-mail to a designated address.

    Excel Export
    All data is automatically exported to spreadsheet for in depth analysis.

    The G210 Invicell Plus – Extra Safety Added

    G210 InviCell Plus is designed to meet the increasing demands for external independent monitoring

    Continuous pH Measurements

    pH is a crucial parameter in embryo culturing. With the G210 InviCell Plus, pH can be measured continuously. By reading the pH in one dedicated chamber, you have the pH for all chambers.

    The G210 InviCell Plus is based on a built-in connection to the pH Online System by MTG with the following characteristics:

    By connecting the G210 InviCell Plus with the pH online System and placing a special pre-calibrated dish with media in the chamber pH is continuously monitored

    Infrared monitoring Resolution of 0.01 pH and an accuracy of +- 0.03 pH Range 5.5 – 9.0 pH

    incubator-diagram

    Independent Temperature Monitoring

    The G210 InviCell plus is prepared for individual temperature monitoring of each culture chamber in G210.

    Monitor Temperature Sensors are isolated from the Control sensors or any part of the Incubator control system

    The system is based on 10 individual Temperature Sensors. One for each chamber.

    Sensor interface board is electrically isolated from the G210 Incubator Control system and has its own Power supply

    Independent External Gas Monitoring

    To perform true independent monitoring, it is critical to measure the exact point prior to the gas entering the chambers.

    In the G210 InviCell Plus a special gas system access chamber has been installed to allow for this.

    An external sensor can be placed in the gas line just before the chambers.

    The sensor can be read independently of the G210.

    The sensor is powered independently.

    GasMixerChamber

    Space saving with the Stacking System for the G210

    The unique Stacking System has capacity for 3 incubators

    G210 InviCell

    Dimensions (WxDxH) mm
    860x550x170
    Weight
    45 kg
    Temperature range ambient to
    42.9oC
    CO₂ / O₂ range
    2-10% / 2-20%
    Connection to 100% CO2 and 100% N2
    Yes
    Gas consumption (Typically)
    1 l/h CO₂& 5 l/h N₂
    Datalogger system – K-Link
    Yes
    External Alarm Port
    Yes
    Power consumption
    Max: 270 W
    Avg: 65 W chamber 37oC
    Ambient humidity and temperature
    Max 75% RH & 20-30oC
    Heating plates
    NUNC/Falcon/Vitrolife
    Prepared for pH
    No
    Prepared for external monitoring
    No
    No of temperature sensors
    11

    G210 InviCell Plus

    Dimensions (WxDxH) mm
    860x550x170
    Weight
    46 kg
    Temperature range ambient to
    42.9oC
    CO₂ / O₂ range
    2-10% / 2-20%
    Connection to 100% CO2 and 100% N2
    Yes
    Gas consumption (Typically)
    1 l/h CO₂& 5 l/h N₂
    Datalogger system – K-Link
    Yes
    External Alarm Port
    Yes
    Power consumption
    Max: 270 W
    Avg: 65 W chamber 37oC
    Ambient humidity and temperature
    Max 75% RH & 20-30oC
    Heating plates
    NUNC/Falcon/Vitrolife
    Prepared for pH
    Yes
    Prepared for external monitoring
    CO2 + Temperature
    No of temperature sensors
    21
    Part Number Part Description
    60000 G210 InviCell Plus Optional pH and External Monitoring
    59500 G210 InviCell
    23063-1 Falcon dish inserts
    23064-1 Nunc dish inserts
    23069 Vitrolife dish inserts
    23061-1 Falcon pH dish inserts for G210 InviCell Plus
    23060-1 Nunc pH dish inserts for G210 InviCell Plus
    23079 Vitrolife pH dish inserts for G210 InviCell Plus

    Order codes for additional features and options

    Part Number Part Description
    23050-110-O Stacking System 120V for 3 pcs. G210/G18
    23050-230-O Stacking System 230V for 3. pcs. G210/G185
    59655 XLR6 Alarm Connector
    11010 F100 Thermometer
    11010P1 F100 Thermometer, calibrated with 1 probe
    11010P2 F100 Thermometer, calibrated with 2 probes
    11006 STS Sensor Temperature sensor for validation
    18002 OCTAX Log & Guard pH Controller
    18004 OCTAX Log & Guard pH Online Sensor
    18005 OCTAX pH Online Reference Dish
    53830 HEPA Inline disc filter for G185/G210
    22166 HEPA/VOC Filter for G185/G185ST
    59558 K-720 HEPA/VOC Filter (G210 a-models) (pack of 2)
    59556 K-730 HEPA/VOC Filter (G210 b-models) (pack of 2)
    59922 Lid Plugs for G210 (pack of 10)