G210 InviCell
Long Term Incubator
Encapsulating 20 years of incubator development, the G210 InviCell incubator combines optimal embryo growth conditions with advanced user control. It is the ideal incubation solution for a busy clinic.
- Defining, Creating, Monitoring and constantly sustaining the optimal environment for human embryos
- Thoughtful design and advanced user control options make everyday work with the G210 effective, safe and comfortable
- With its compact size, low daily running costs and the option of a stacking system the G210 is the ideal solution for a busy Clinic
Combining optimal embryo growth conditions with advanced user control
Key Features of G210 InviCell and G210 InviCell Plus
Space Saving
Ten individual incubation chambers to ensure minimal stress and risk of cross contamination for the embryos. Significant space saving
Heating
Dedicated heating plates with grooves ensure direct heat transfer to the dish
Responsive Gas Control
Set the required specifications to mix CO2 and O2. Uses pure CO2 and N2 (optional)
Optimal Environment
Embryo conditions, including pH levels, are kept completely stable through advanced and accurate software control of gas and temperature thus providing stress free incubation
Ambient humidity
The G210 is an incubator with ambient humidity which strongly minimizes the risk of fungal growth inside the incubator and makes it easier to clean
Safe
Electro-magnetic fields eliminated by non-inductive EM Neutra™ technology (patented)
Superior Filtering and Hygiene
High efficiency particle filter to remove airborne particles. VOC filter to remove organic compounds
Tracking and Alarm
Data logging and alerts with K-Link™ extensive ethernet based monitoring
Advanced User Control
Advanced intuitive user interface with dedicated security system
Economical
Low running costs because of low gas consumption and use of pure gas
Independent External monitoring
An option for independent external monitoring of key parameters including temperature and gas concentration
Certified
CE Marked
Optimal Environment for Human Embryos
Decreasing embryo stress is a key factor in long term incubation.
The G210 has several characteristics to ensure minimal stress.
Highly stable environment of both gas and temperature
VOC filter, HEPA14 filter and UV light* (*Not available in the USA) ensuring clean air in the chambers
Individual chambers for each patient- 10 in total
Optimal temperature conditions at all times. The advanced heating system of the G210 ensures constant and all-embracing heating in the chambers
- Each isolated chamber has its own temperature sensor to ensure quick and accurate temperature control of all 6 sides in the chamber
- The unique non-inductive EM NeutraTM heating system gives no electro-magnetic fields around the embryos
- Emulate the natural cycle of basal body temperature with the advanced software based heating technology
Embryo conditions including pH levels are kept stabile through the combination of accurate gas and temperature control.
- Increased accuracy and stability with dedicated gas control algorithms
- The built-in advanced gas mixer allows gas concentration to be set at the required level
- Ambient humidity based incubation significantly reduces the risk for fungal growth and cross contamination
- The unidirectional gas flow system ensures even gas distribution throughout the chambers
- To optimize recovery time and keep gas consumption low, gas flow is paused when the lid is open
Advanced User Control
Large 7“ touch-screen display gives you intuitive control of all
parameters and on screen data display.
A quick overview of each chamber and key parameters on screen
Enter patient data directly on the screen for each individual. No more writing on the device with markers or pens
Multi-level password protection ensures no unintended access to settings
Graphic display of key parameters over time
React quickly to changes in the incubator with the extensive audible and visible monitoring and alarms. Alarms can easily be transferred to the hospital central monitoring system.
Temperature – Gas – Service needs
Keep Track of Incubator from anywhere in the Clinic
K-Link Ethernet based monitoring system
Monitor all your incubators directly from your office. The K-Link Ethernet based software provides external monitoring of all key parameters in your G210 InviCell. Multiple G210s can be monitored from the same PC.
Parameters continuously monitored with K-Link:
– Temperature per chamber
– CO2 and O2 levels
– Gas pressure and consumption
– Alarms and warnings
– Service requirements
K-Link E-mail alerts
In case of an alarm K-Link can be set up to automatically send an e-mail to a designated address.
Excel Export
All data is automatically exported to spreadsheet for in depth analysis.
The G210 Invicell Plus – Extra Safety Added
G210 InviCell Plus is designed to meet the increasing demands for external independent monitoring
Continuous pH Measurements
pH is a crucial parameter in embryo culturing. With the G210 InviCell Plus, pH can be measured continuously. By reading the pH in one dedicated chamber, you have the pH for all chambers.
The G210 InviCell Plus is based on a built-in connection to the pH Online System by MTG with the following characteristics:
By connecting the G210 InviCell Plus with the pH online System and placing a special pre-calibrated dish with media in the chamber pH is continuously monitored
Infrared monitoring Resolution of 0.01 pH and an accuracy of +- 0.03 pH Range 5.5 – 9.0 pH
Independent Temperature Monitoring
The G210 InviCell plus is prepared for individual temperature monitoring of each culture chamber in G210.
Monitor Temperature Sensors are isolated from the Control sensors or any part of the Incubator control system
The system is based on 10 individual Temperature Sensors. One for each chamber.
Sensor interface board is electrically isolated from the G210 Incubator Control system and has its own Power supply
Independent External Gas Monitoring
To perform true independent monitoring, it is critical to measure the exact point prior to the gas entering the chambers.
In the G210 InviCell Plus a special gas system access chamber has been installed to allow for this.
An external sensor can be placed in the gas line just before the chambers.
The sensor can be read independently of the G210.
The sensor is powered independently.
Space saving with the Stacking System for the G210
The unique Stacking System has capacity for 3 incubators
G210 InviCell
Avg: 65 W chamber 37oC
G210 InviCell Plus
Avg: 65 W chamber 37oC
Part Number | Part Description |
---|---|
60000 | G210 InviCell Plus Optional pH and External Monitoring |
59500 | G210 InviCell |
23063-1 | Falcon dish inserts |
23064-1 | Nunc dish inserts |
23069 | Vitrolife dish inserts |
23061-1 | Falcon pH dish inserts for G210 InviCell Plus |
23060-1 | Nunc pH dish inserts for G210 InviCell Plus |
23079 | Vitrolife pH dish inserts for G210 InviCell Plus |
Order codes for additional features and options
Part Number | Part Description |
---|---|
23050-110-O | Stacking System 120V for 3 pcs. G210/G18 |
23050-230-O | Stacking System 230V for 3. pcs. G210/G185 |
59655 | XLR6 Alarm Connector |
11010 | F100 Thermometer |
11010P1 | F100 Thermometer, calibrated with 1 probe |
11010P2 | F100 Thermometer, calibrated with 2 probes |
11006 | STS Sensor Temperature sensor for validation |
18002 | OCTAX Log & Guard pH Controller |
18004 | OCTAX Log & Guard pH Online Sensor |
18005 | OCTAX pH Online Reference Dish |
53830 | HEPA Inline disc filter for G185/G210 |
22166 | HEPA/VOC Filter for G185/G185ST |
59558 | K-720 HEPA/VOC Filter (G210 a-models) (pack of 2) |
59556 | K-730 HEPA/VOC Filter (G210 b-models) (pack of 2) |
59922 | Lid Plugs for G210 (pack of 10) |